FLIR A300 f / FLIR A310 f / FLIR A310 pt


The information below outlines key features that contribute to FLIR A-Series infrared cameras world class performance.

 

 

IP66 FLIR A300f / A310fThe FLIR A300 / A310 can be ordered in an environmental housing. The housing increases the environmental specifications of the FLIR A300 / A310 to IP66, without effecting any of the camera features. It is ideal when the camera needs to be installed in dusty or wet environments. The housing is available for A300 cameras that are equipped with a 25º or 45º lens and A310 cameras that are equipped with a 25º, 45º or 90º lens.

Users that want to build in the camera in the housing themselves or that already have a FLIR A300 or A310 that needs to be extra protected against dust and water can order the housing separately as an accessory.

video output FLIR A300 / FLIR A310 housing options

  • FLIR A300f / A310f: The FLIR A300f and A310f are thermal imaging cameras with an environmental housing protecting the A300 or A310 against dust and water. The housing increases the environmental specifications of the FLIR A300 / A310 to IP66, without effecting any of the camera features.
  • FLIR A310pt: The FLIR A310pt pan/tilt has all the necessary features and functions to build single- or multi-camera solutions. The FLIR A310pt can pan +/- 360º continuous and tilt +/- 45º. It is ideal to cover large areas. Typical application examples are coal pile, waste bunker and sub-station monitoring, the FLIR A310pt utilizes standard Ethernet hardware and software protocols. The FLIR A310pt is a multi-sensor and includes a lowlight 36x zoom color CCD camera.
measurement kopie Built-in extensive analysis functions (only FLIR A310)Spot, area measurement and difference temperature functions.
alarms kopie Built-in alarm functions (only FLIR A310)As function of analysis, internal temperature or digital input.
modbus Ethernet/IP and Modbus TCP compliance (only FLIR A310)Easy sharing of analysis, alarm results to PLC:s.
messaging kopie Messaging functionality (only FLIR A310)The camera automatically sends analysis results, IR images and more as an e-mail on schedule or at alarm. Autonomous dispatch of files or e-mails, acting as an FTP- or SMTP-client.
masking kopie Image masking functionality (only FLIR A310)Select only the relevant part of the image for your analysis.
mpeg4 kopie MPEG-4 streamed videoMPEG-4 streamed video output over Ethernet to show live images on a PC, 640×480 with overlay up to 30 Hz, system dependent.
power over ethernet kopie PoE (Power over Ethernet)Communication and power supplied with only one cable.
digital kopie Digital inputs/outputs (only FLIR A310)For alarms and control of external equipment.
ir monitor software kopie IR monitor softwareIn house developed software with support to up to nine cameras simultaneously.
video output Video outputComposite video output, PAL and NTSC compatible.
lens_25° kopie LensBuilt-in 25 degree lens with both motorized focus and autofocus. Optional lenses available.

< 50 mK thermal sensitivity captures the finest image details and temperature difference information.

remote control wireless kopie Remote controlRemote control of the camera over the Web and TCP/IP protocol.
16 bit 16 bit image16 bit image transfer to PC for analysis.
100MB Built-in 100 Mb Ethernet connection100 Mb Ethernet.

 

Brochure Download

FLIR A310 f (A4)

Automation Catalogue

 

 

 

FLIR A315 FLIR A615
Imaging and optical data
Spatial resolution (IFOV) 1.36 mrad 0.69 mrad
Focal length 18 mm 24.5 mm
F-number 1.3 1.0
Image frequency 60 Hz 50 Hz (100/200 Hz with windowing)
Detector data
IR resolution 320 × 240 pixels 640 × 480 pixels
Detector pitch 25 μm 17 μm
Detector time constant Typical 12 ms Typical 8 ms
Measurement
Object temperature range –20 to +120°C0 to +350°C -20 to +150°C+100 to +650°C+300 to +2000°C
USB
USB N/A Control and image
USB, standard N/A USB 2 HS
USB, connector type N/A USB Mini-B
USB, communication N/A TCP/IP socket-based FLIR proprietary
USB, image streaming N/A 16-bit 640 × 480 pixels at 25 Hz16-bit 640 × 240 pixels at 50 Hz16-bit 640 × 120 pixels at 100 Hz

– Signal linear

– Temperature linear

– Radiometric

USB, protocols N/A TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet
Ethernet, image streaming 16-bit 320 × 240 pixels at 60 Hz- Signal linear- Temperature linear

– Radiometric

GigE Vision and GenICam compatible

16-bit 640 × 480 pixels at 50 Hz16-bit 640 × 240 pixels at 100 Hz16-bit 640 × 120 pixels at 200 Hz

– Signal linear

– Temperature linear

– Radiometric

GigE Vision and GenICam compatible

FLIR A315 – Standard FLIR A315f – Environmental housing FLIR A615 – Standard
Environmental data
Operating temperature range –15°C to +50°C –25°C to +50°C –15°C to +50°C
Encapsulation IP 40 (IEC 60529) IP 66 (IEC 60529) IP 40 (IEC 60529)
Bump 25 g (IEC 60068-2-29) 5 g, 11 ms (IEC 60068-2-27) 25 g (IEC 60068-2-29)
Physical data
Weight 0.7 kg 5 kg 0.9 kg
Camera size (L × W × H) 170 × 70 × 70 mm 460 × 140 × 150 mm 216 x 73 x 75 mm
Tripod mounting UNC ¼”-20 (on three sides) N/A UNC ¼”-20 (on three sides)
Base mounting 2 × M4 thread mounting holes
(on three sides)
TBA 2 × M4 thread mounting holes
(on three sides)
System features
Automatic heaters N/A Clears ice from window N/A

General

 

Imaging and optical data
Field of view (FOV) / Minimum focus distance 25° × 18.8° / 0.4 m
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C @ +30°C / 50 mK
Focus Automatic or manual (built in motor)
Detector data
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–13 μm
Measurement
Accuracy ±2°C or ±2% of reading
Measurement analysis
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global object parameters
Ethernet
Ethernet Control and image
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, type Gigabit Ethernet
Ethernet, communication TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Digital input/output
Digital input 2 opto-isolated, 10–30 VDC
Digital output, purpose Output to ext. device (programmatically set)
Digital output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Digital input, purpose Image tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
Power system
External power operation 12/24 VDC, 24 W absolute max
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Digital input/output
Digital input, purpose Image tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
Environmental data
Storage temperature range –40°C to +70°C
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC • EN 61000-6-2:2001 (Immunity)• EN 61000-6-3:2001 (Emission)• FCC 47 CFR Part 15 Class B (Emission)
Vibration 2 g (IEC 60068-2-6)
Physical data
Housing material Aluminium
Scope of delivery
Hard transport case or cardboard box, Infrared camera with lens, Utility CD-ROM, Calibration certificate, Ethernet™ cable, USB cable (FLIR A615), Mains cable, Power cable (pig-tailed), Power supply, Printed Getting Started Guide, Printed Important Information Guide, User documentation CD-ROM, Warranty extension card or Registration card, 6-pole screw terminal (mounted on camera)