FLIR A305 sc / A325 sc / A645 sc / A655 sc


The FLIR A305 sc – A325 sc and FLIR A645 sc – A655sc infrared cameras are designed to keep the thermal efficiency of your development project under constant control. It prevents design faults in the making, ensures quality and cuts time-to-market.

640x480 kopie 640×480 pixel resolution

Some models of the A sc-Series have a resolution pixel detector of 640×480 pixels that allows more accuracy and shows more details at a longer distance.

high speed windw

High speed infrared windowing

The FLIR SC655 model has a high speed infrared windowing function. It allows you to record thermal images at a frame rate up to 200Hz by windowing.

streaming kopie

Conditional start/stop

Control start/stop recording in FLIR R&D software. Let an external signal control the image streaming.

sensiti

High sensitivity < 50 mK

< 50 mK thermal sensitivity captures the finest image details and temperature difference information.

lightweight kopie

Compact & lightweight design

Compact thermal imaging cameras for fixed R&D installations from FLIR.

gige kopie

GigE Vision™ standard compatibility

An industry first. GigE Vision is a new camera interface standard developed using the Gigabit Ethernet communication protocol. GigE Vision is the first standard to allow for fast image transfer using low cost standard cables even over long distances. With GigE Vision, hardware and software from different vendors can interoperate seamlessly over GigE connections.

genicam kopie

GenICam™ protocol support

An industry first. The goal of GenICam is to provide a generic programming interface for all kinds of cameras. Regardless of interface technology (GigE Vision, Camera Link, 1394 DCAM, etc.) or features implemented, the application programming interface (API) will always be the same. The GenICam protocol also makes third party software being possible to use with the camera.

ethernet kopie

Built-in Gigabit Ethernet connection

Real time 16 bit image streaming.

FLIR SC-Series camera model comparison

 FLIR A305 sc FLIR A325 sc  FLIR A645 sc

FLIR A655 sc

Image size 320 x 240 pixels 320 x 240 pixels 640 x 480 pixels 640 x 480 pixels
Image frequency 9 Hz 60 Hz 25 Hz 50 Hz Windowing option: 100/200 Hz
Temperature range –20 °C to +350 °C

in 2 ranges

(+1200°C optionally)

–20 °C to +350 °C

in 2 ranges

(+1200°C optionally)

–20 °C to +650°C

in 2 ranges

(+2000°C optionally)

–20 °C to +650°C

in 2 ranges

(+2000°C optionally)

Ethernet image streaming 16-bit 320 × 240 pixels at 9 Hz 16-bit 320 × 240 pixels at 60 Hz 16-bit 640 × 480 pixels at 25 Hz 16-bit 640 × 480 pixels at 50 Hz

Up to 200Hz by windowing

USB N/A N/A Control and image Control and image
USB communication N/A N/A TCP/IP socket-based FLIR proprietary and GenICam TCP/IP socket-based FLIR proprietary and GenICam
USB image streaming N/A N/A 16-bit 640 × 480 pixels at 25 Hz 16-bit 640 × 480 pixels at 25 Hz

Up to 100Hz by windowing

 

 

 

 

Category:

Infrared cameras are designed to keep the thermal efficiency of your development project under constant control.

 

FLIR A305 sc FLIR A325 sc FLIR A645 sc FLIR A655 sc
Imaging and optical data
Focal length 18 mm (0.7 in.) 18 mm (0.7 in.) 24.6 mm (0.97 in.) 24.6 mm (0.97 in.)
Spatial resolution (IFOV) 1.36 mrad 1.36 mrad 0.69 mrad 0.69 mrad
F-number 1.3 1.3 1.0 1.0
Image frequency 9 Hz 60 Hz 25 Hz 50 Hz (100/200 Hz with windowing)
Detector data
IR resolution 320 × 240 pixels 320 × 240 pixels 640 × 480 pixels 640 × 480 pixels
Detector pitch 25 μm 25 μm 17 μm 17 μm
Measurement
Object temperature range –20 to +120°C
0 to +350°C(+1200°C as an option)
–20 to +120°C
0 to +350°C
(+1200°C as an option)
–20 to +120°C
100 to +650°C
(+2000°C as an option)
–20 to +120°C
100 to +650°C
(+2000°C as an option)
USB
USB N/A N/A Control and image USB, standard USB 2 HS Control and image USB, standard USB 2 HS
USB, connector type N/A N/A USB Mini-B USB Mini-B
USB, communication N/A N/A TCP/IP socket-based FLIR proprietary and GenICam protocol TCP/IP socket-based FLIR proprietary and GenICam protocol
USB, image streaming N/A N/A 16-bit 640 × 480 pixels at 25 Hz

– Signal linear

– Temperature linear

– Radiometric

16-bit 640 × 480 pixels at 25 Hz Up to 100Hz by windowing

– Signal linear

– Temperature linear

– Radiometric

USB, protocols N/A N/A TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet
Ethernet, image streaming 16-bit 320 × 240 pixels at 9 Hz

– Signal linear

– Temperature linear

– Radiometric

GigE Vision and GenICam compatible

16-bit 320 × 240 pixels at 60 Hz

– Signal linear

– Temperature linear

– Radiometric

GigE Vision and GenICam compatible

16-bit 640 × 480 pixels at 25 Hz

– Signal linear

– Temperature linear

– Radiometric

GigE Vision and GenICam compatible

16-bit 640 × 480 pixels at 50 Hz

Up to 200Hz by windowing

– Signal linear

– Temperature linear

– Radiometric

GigE Vision and GenICam compatible

General specifications

Imaging and optical data
Field of view (FOV) / Minimum focus distance 25° × 19° / 0.25 m (0.82 ft.)
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C at +30°C (+86°F) / 50 mK
Focus Automatic or manual (built in motor)
Imaging performance
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–14 μm
Measurement
Accuracy ±2°C (±3.6°F) or ±2% of reading
Measurement analysis
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global object parameters
Ethernet
Ethernet Control and image
Ethernet, type Gigabit Ethernet
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, communication TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Digital input/output
Digital input, purpose Image tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
Digital input 2 opto-isolated, 10–30 VDC
Digital output, purpose Output to ext. device (programmatically set)
Digital output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Power system
External power operation 12/24 VDC, 24 W absolute max
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Environmental data
Operating temperature range –15°C to +50°C (+5°F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
EMC • EN 61000-6-2:2001 (Immunity)

• EN 61000-6-3:2001 (Emission)

• FCC 47 CFR Part 15 Class B (Emission)

Encapsulation IP 40 (IEC 60529)
Bump 25 g (IEC 60068-2-29)
Vibration 2 g (IEC 60068-2-6)
Physical data
Weight 0.9 kg (1.98 lb.)
Camera size (L × W × H) 170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.) for FLIR SC305- SC325 216 x 73 x 75 mm (8.5 x 2.9 x 3.0 in.) for FLIR SC645 – SC655
Tripod mounting UNC ¼”-20 (on three sides)
Base mounting 2 × M4 thread mounting holes (on three sides)
Housing material Aluminium
Scope of delivery
Hard transport case or cardboard box, Infrared camera with lens, Application CD-ROM, Calibration certificate, Ethernet™ cable, USB cable (FLIR A645 sc and FLIR A655 sc only), Mains cable, Power cable, pig-tailed, Power supply, Printed Getting Started Guide, Printed Important Information Guide, User documentation CD-ROM, Warranty extension card or Registration card